Three-phase UPS. Know your system. Explore APC, Eaton, Vertiv and Xtreme Power Conversion families. Find the electrical configuration, check the manufacturer reference and start a service or replacement assessment.
Choose a service or project
Find your model family Manufacturer specifications describe a family. Your nameplate, installed modules, batteries and bypass determine the configuration at your site. Each reference has three-phase input and output; voltage choices depend on the exact variant.
Family or manufacturer ManufacturerAll manufacturers APC / Schneider Electric Eaton Vertiv / Liebert Xtreme Power Conversion (XPC) Voltage variantAll voltages 208 V 480 V ArchitectureAll architectures Modular / scalable Fixed / monolithic Reset filters
No matching family. Reset a filter or send your nameplate for review.
APC / Schneider Electric
Galaxy VS Family reference
Edge and midsize data centres
Modular power protection with different capacity ranges for each voltage. Match the complete catalogue number to the site supply.
Published range 10-75 kW (208 V); 20-150 kW (480 V)
Three-phase input and output 208 / 480 V Check at your site Input and output voltage, installed modules and battery arrangement.
Discuss this system: Galaxy VS View model details: Galaxy VS Manufacturer reference: Galaxy VS Eaton
93PM Family reference
Facility and data-centre power
The selected 250 kW frame uses modular power stages. Installed capacity and redundant capacity depend on the module configuration.
Published range 50-250 kW
Three-phase input and output 480 V Check at your site Generation, frame, modules, bypass and exact battery cabinet.
Discuss this system: 93PM View model details: 93PM Manufacturer reference: 93PM Eaton
93E Discontinued: installed systems
Existing installations
Eaton marks this family as discontinued. Use the reference for installed-system maintenance or replacement planning.
Published range 20-60 kVA / 16-48 kW
Three-phase input and output 208 / 220 V Check at your site Nameplate, battery age, service history and replacement path.
Discuss this system: 93E View model details: 93E Manufacturer reference: 93E Xtreme Power Conversion (XPC)
E91 Family reference
Compact facility installations
A fixed-capacity online UPS with internal VRLA batteries. This reference covers E91-10K, E91-15K and E91-20K.
Published range 10-20 kW
Three-phase input and output 208Y/120 V Check at your site Exact model, internal batteries, external cabinets and bypass access.
Discuss this system: E91 View model details: E91 Manufacturer reference: E91 Xtreme Power Conversion (XPC)
M90U Family reference
Modular facility power
A modular online UPS with internal battery modules. Redundant capacity must be checked against the installed modules and actual load.
Published range 15-60 kW
Three-phase input and output 208Y/120 V Check at your site Module ratings and count, protected load and battery-module population.
Discuss this system: M90U View model details: M90U Manufacturer reference: M90U Manufacturer image; configuration may vary. Selected regional variants. Exact configuration and availability confirmed for each request.
Compare the configuration A voltage match is the first check. Capacity ranges describe selected manufacturer variants, and kVA and kW are separate ratings where shown. Modular construction alone does not establish redundant capacity.
Compare two families Choose two of the shown families to compare their published configuration and site checks.
First familyChoose a family APC / Schneider Electric · Galaxy VS APC / Schneider Electric · Galaxy VL Eaton · 93PM Eaton · 93E Vertiv / Liebert · Liebert EXM Vertiv / Liebert · Liebert EXL S1 Xtreme Power Conversion (XPC) · E91 Xtreme Power Conversion (XPC) · M90U Second familyChoose a family APC / Schneider Electric · Galaxy VS APC / Schneider Electric · Galaxy VL Eaton · 93PM Eaton · 93E Vertiv / Liebert · Liebert EXM Vertiv / Liebert · Liebert EXL S1 Xtreme Power Conversion (XPC) · E91 Xtreme Power Conversion (XPC) · M90U Clear comparison
Selected regional variants. Exact configuration and availability confirmed for each request.
Before choosing a UPS The filter narrows published family references. An equipment choice requires measured load, runtime, redundancy, bypass and site electrical review.
Load, kW and kVA, growth, redundancy and runtime.
How each is built, scaled and serviced.
N, N+1, 2N and what counting modules misses.
What each bypass does and when the load uses it.
Compare column Voltage variants Published capacity Construction Planning check Service request
Swipe horizontally to see all comparison columns.
No matching family. Reset a filter or send your nameplate for review.
Family Voltage variants Published capacity Construction Planning check Service request APC / Schneider Electric Galaxy VS Family reference 208 / 480 V 10-75 kW (208 V); 20-150 kW (480 V) Modular / scalable Input and output voltage, installed modules and battery arrangement. Discuss this system: Galaxy VS APC / Schneider Electric Galaxy VL Family reference 480 V 200-500 kW Modular / scalable Frame rating, module population, bypass cabinet and battery system. Discuss this system: Galaxy VL Eaton 93PM Family reference 480 V 50-250 kW Modular / scalable Generation, frame, modules, bypass and exact battery cabinet. Discuss this system: 93PM Eaton 93E Discontinued: installed systems 208 / 220 V 20-60 kVA / 16-48 kW Fixed / monolithic Nameplate, battery age, service history and replacement path. Discuss this system: 93E Vertiv / Liebert Liebert EXM Family reference 208 / 480 V 10-200 kW (208 V); 50-250 kW (480 V) Modular / scalable Voltage variant, installed capacity, maintenance bypass and distribution. Discuss this system: Liebert EXM Vertiv / Liebert Liebert EXL S1 Family reference 480 V 250-1200 kW Fixed / monolithic Unit rating, parallel arrangement, switchgear and energy storage. Discuss this system: Liebert EXL S1 Xtreme Power Conversion (XPC) E91 Family reference 208Y/120 V 10-20 kW Fixed / monolithic Exact model, internal batteries, external cabinets and bypass access. Discuss this system: E91 Xtreme Power Conversion (XPC) M90U Family reference 208Y/120 V 15-60 kW Modular / scalable Module ratings and count, protected load and battery-module population. Discuss this system: M90U
Prepare the site assessment Existing system: send the full model and serial number, nameplate voltage, battery arrangement and service history.Replacement: include measured load, expected growth, required runtime, input and output voltages, bypass arrangement and room access.Service window: identify the protected load, available shutdown period and who can approve switching.Choose UPS maintenance for installed equipment, installation and commissioning for a planned start-up, or replacement planning before changing the power path.
Questions Can I request service for a model that is not listed? Yes. Send the complete nameplate model through the quote form. The service scope is assessed for the installed configuration.
Does a listed model mean it is in stock? The list is an equipment reference. Supply, exact regional configuration, lead time and service scope are confirmed for each request.
Does the filter select a UPS for my load? The filter narrows published family references. An equipment choice requires measured load, runtime, redundancy, bypass and site electrical review.
Sources, checked 2026-10-06:
Reference Schneider Electric Canada, Galaxy VS 10-75 kW (208 V), 20-150 kW (480 V) Brochure Reference Schneider Electric Canada, Galaxy VL family Reference Eaton Canada, 93PM 480V UPS, selected 250 kW frame Reference Eaton Canada, 93E UPS, discontinued family reference Reference Vertiv, Liebert EXM North American family variants Reference Vertiv, Liebert EXL S1 250-1200 kW, 480 V brochure Reference Xtreme Power Conversion, E91-10K / E91-15K / E91-20K specifications Reference Xtreme Power Conversion, M90U 15-60 kW specifications Reference Schneider Electric, Galaxy VS 208 V input/output specifications Reference Schneider Electric, Galaxy VL 480 V connections Reference Vertiv, Liebert EXM brochure, input/output specification table Reference Vertiv Canada, data centre and facility three-phase UPS portfolio