Three-phase UPS service
Data-centre UPS service across Canada Maintenance, battery testing, installation and repair. A written method before work, recorded readings and a report after.
Battery testing or replacement
Plan battery replacement Investigate declining runtime or plan a string replacement.
Plan battery replacement Equipment illustration Manufacturer image; configuration may vary. Selected regional variants. Exact configuration and availability confirmed for each request.
Explore three-phase UPS models APC, Eaton, Vertiv and XPC. Match your nameplate to a researched family, then plan maintenance or replacement.
Browse the model library APC / Schneider Electric
Galaxy VS Family reference
10-75 kW (208 V); 20-150 kW (480 V) 208 / 480 V
Eaton
93PM Family reference
50-250 kW 480 V
Vertiv / Liebert
Liebert EXM Family reference
10-200 kW (208 V); 50-250 kW (480 V) 208 / 480 V
Xtreme Power Conversion (XPC)
E91 Family reference
10-20 kW 208Y/120 V
Choose a service or project
Published range. Manufacturer image; configuration may vary.
Selected regional variants. Exact configuration and availability confirmed for each request.
How quickly we respond 4 h Reply and quote: within 4 business hours
Same day Same day: Montreal, Quebec City, Toronto, Ottawa
24 to 48 h Elsewhere in Canada: 24 to 48 hours
24/7 Emergency line: 24/7
Plan service or testing
Find the work your UPS needs Start with the purpose of the visit. The scope is confirmed against your equipment and site.
I need Scheduled UPS maintenance Battery testing or replacement A maintenance contract A load bank test Installation and commissioning Replacement planning Thermography and power quality Scheduled UPS maintenance
Define the next maintenance visit.
Scope to confirm Inspection, operating readings, battery checks and findings against the previous visit.
Have ready, if known UPS model and rating, last report, battery age and permitted service window. Battery testing or replacement
Investigate declining runtime or plan a string replacement.
Scope to confirm Ohmic trends, capacity testing where specified, replacement scope and disposal requirements.
Have ready, if known Battery model, number of strings, installation date and required runtime. A maintenance contract
Set the visits, reports and response terms in writing.
Scope to confirm Equipment schedule, preventive visits, battery scope, parts and call-out terms.
Have ready, if known Equipment list, existing agreement, access hours and reporting requirements. A load bank test
Check the power train under a defined artificial load.
Scope to confirm Connection point, load steps, hold times, transfers and recorded output readings.
Have ready, if known UPS rating, single-line diagram, bypass arrangement and test window. Installation and commissioning
Prepare a documented handover for a new or moved UPS.
Scope to confirm Site checks, startup procedure, functional tests and acceptance records.
Have ready, if known Model, electrical supply, room access, load and target commissioning date. Replacement planning
Assess an ageing system before committing to its replacement.
Scope to confirm Equipment condition, support status, load, redundancy and replacement constraints.
Have ready, if known Equipment inventory, recent faults, load profile and planned growth. Thermography and power quality
Investigate hot connections or supply disturbances.
Scope to confirm Infrared findings and power-quality measurements within an agreed scope.
Have ready, if known Symptoms, circuit information, operating load and previous readings. What keeps a data-centre UPS ready A data-centre UPS stays ready with scheduled maintenance, batteries tested on a schedule, a load test from time to time, and a plan for the day it reaches end of life. Vertiv's reliability analysis indicates that UPS receiving two preventive maintenance visits a year have a mean time between failures 23 times higher than UPS with none. The services cover maintenance, battery testing and replacement, installation and commissioning, contracts, repair and replacement planning, and every figure quoted here links to the manufacturer document or standard it comes from.
See the maintenance scope Fig. 1 · Where a maintenance visit looks
The numbered callouts follow the order of a maintenance visit. See the maintenance scope What a visit checks, how often, and the report.
Ohmic trending, capacity tests and replacement.
What to do when a UPS fails, and how repairs run.
All 7 services
Load bank testing Load bank testing Fig. 2 · Load steps and hold times
Load steps and hold times A step chart of load on the UPS output against time: 50% load held for one hour, then 100% load held for three hours. Load on the UPS output Time 50% one hour 100% three hours Then: battery discharge, repeated transfers, load removed. Load steps from Eaton's UPS load bank procedure; the maker's method for each model sets its own. Source: Eaton, Load Bank Testing Scope of Work (Attachment L-6) Fig. 3 · Load bank test power path
Load bank test power path The supply feeds the UPS rectifier and inverter; the inverter output feeds the load bank; the critical load is carried on the maintenance bypass from the supply, outside the UPS. Supply UPS under test Rectifier Inverter Battery Load bank Test load Maintenance bypass Critical load During the test the critical load runs on the maintenance bypass (dashed) and the load bank is connected to the UPS output, so the test load never reaches the protected equipment. What a load bank test proves A load bank test proves that the UPS carries a known load at each step and keeps its output in order while it does, with the protected equipment on a separate path. In Eaton's published UPS method the load runs at 50% for one hour and at 100% for 3 hours, followed by a short battery discharge and repeated transfers, and a report documents the results.
Load bank testing, explained
How a job runs You tell us the site, the UPS make and size if known, the service and the timing.We reply and quote within 4 business hours.A written method is agreed before the visit: what is checked, how the load is protected, who signs off.The work follows the maker's procedure for your model, with readings recorded as they are taken.The report sets out findings, readings against the last visit, work done and what comes next.More on how we work , or contact us for an emergency.
The report Report layout, example
Findings OK Watch Act
Equipment: UPS model, serial number, firmware, configuration and battery stringsMethod: The procedure followed, the load protection used and who signed off each stepReadings: Input, output and bypass values; battery readings per block; temperaturesLoad steps: Each step applied in a load test, its duration and what was measuredThermal findings: Hot spots with their temperatures and a thermograph of eachFindings: What is out of range, why it matters and how urgent it isNext steps: Work recommended, components near end of life, the date of the next visitEngineering guides Rectifier, battery, inverter, bypass and the modes.
Standby, line-interactive, double conversion, multi-mode.
N, N+1, 2N and what counting modules misses.
Load, kW and kVA, growth, redundancy and runtime.
Life, footprint, temperature, cost and safety.
Real life, temperature, charging and the signs.
All 14 guides
The room around the UPS Explore power distribution, monitoring, cooling, fire protection and contamination control. Each topic connects back to the UPS and battery system.
Power infrastructure PDUs, transfer switches, switchgear, arc flash, generators, power quality. Monitoring overview UPS and battery alarms first, then the room, the software and PUE. Cooling overview Heat load, equipment, airflow, density and maintenance. Fire protection overview Clean agents, early warning, inspection, and the UPS room. Cleaning overview Dust and contamination, schedule, and live-room visits. Questions Which UPS do you service? Three-phase UPS from the main makers in data centres, server rooms, hospitals and industrial sites, all brands. Brand names identify equipment only; we are not the manufacturer.
Where do you work? Across Canada: the same day in Montreal, Quebec City, Toronto and Ottawa, and within 24 to 48 hours at other Canadian sites, with an emergency line that is answered around the clock.
How quickly do I get a quote? Within 4 business hours of your request.
Is load bank testing the same as battery testing? No. A load bank test proves the UPS power train at known load steps; battery runtime is proven by a capacity test. See UPS and battery testing.
Sources, checked 2026-10-04:
Reference Eaton, Load Bank Testing Scope of Work, Attachment L-6 (revised 5/12/2015) , p. 1White paper Vertiv, The effect of regular, skilled preventive maintenance and remote monitoring on critical power system reliability (white paper) , p. 2Reference Schneider Electric Canada, Galaxy VS 10-75 kW (208 V), 20-150 kW (480 V) Brochure Reference Eaton Canada, 93PM 480V UPS, selected 250 kW frame Reference Vertiv, Liebert EXM North American family variants Reference Xtreme Power Conversion, E91-10K / E91-15K / E91-20K specifications Need a UPS serviced, tested or replaced? Tell us the site, the UPS and the timing. We reply and quote within 4 business hours, or call 1 (438) 800-0382